Installation and Operation Manual Chapter 1 Introduction
Egate-100 Ver. 4.0 Functional Description 1-25
User-configurable protocol field compression
User-configurable address and control field compression
Echo request and answer support
Max MRU of 1543 bytes (corresponds to 1536-byte frames)
Not supported: Authentication
• NCP of type BCP, as per RFC 3518, with MACs support according to 802.3.
LCP/BCP status alarms can be included, as per user configuration.
Multilink PPP
Egate-100 allows the establishment of Ethernet service with bandwidths over the
E1/T1 rate by binding up to eight E1 links or up to eight T1 links into one logical
link, using MLPPP. A logical port associated with these E1/T1 links can represent
(n
2Mb)/(n 1.5Mb) of Ethernet traffic where n is the number of links.
MLPPP features include:
• Support of up to 42 MLPPP bundles for E1/T1
• Support of up to eight E1/T1 channels by each bundle
• Unframed or fractional E1/T1 with 31/24 timeslots assigned
• Recovery mechanism upon E1 or T1 link failure: shift from n x E1/T1 to
(n-1) x E1/T1
• Worst case of 16 msec-delay compensation buffer for 64-byte frames. For
larger frames the delay compensation grows linearly: for example, 128-byte
frames with a delay compensation of 32 msec
• Support of packet fragmentation.
The supported MLPPP protocols are:
• LCP (Line Control Protocol) as per RFC 1661
Echo request and answer support
Max MRU of 1543 bytes (corresponds to 1536-byte frames)
• MLPPP as per RFC 1990
• MLPPP extension to LCP as per RFC 1990: supports 24-bit sequence number
• BCP (Bridge Control Protocol) per RFC 3518
• Loop Detection on the LCP level.
Timing
Egate-100 has a single clock domain and functions as the clock master. All
remote units operate in loopback timing (LBT) mode and use Egate-100 as their
timing source.
With SDH/SONET interface, system clock options are:
• SDH/SONET Rx
• Internal clock.
With DS3 interface, the system clock options are: