Chapter 5 Monitoring and Diagnostics Installation and Operation Manual
5-10 Monitoring Performance Egate-100 Ver. 4.0
Parameter Description
RX_THEC_MULTI_ERRO
R
This counter increments on every frame in which the GFP
machine detected an error in more than one bit of the THEC
header
RX_EHEC_MULTI_ERRO
R
This counter increments on every frame in which the GFP
machine detected an error in more than one bit of the EHEC
header
RX_CRC32_ERROR This counter increments on every frame in which the GFP
machine detected an error in the Ethernet CRC or the PFCS (if the
GFP frame contains a PFCS)
Viewing Bridge Statistics
You can access bridge statistics from the Bridge Monitoring menu as illustrated in
Figure
5-14
. This menu also allows you to clear all accumulated bridge statistics.
Egate-100
Main Menu>Monitoring>Application>Bridge
1. MAC Table >
2. View VLAN ID to Bridge Ports []
3. View Bridge Ports to VLAN ID []
4. Statistics >
5. Clear Statistics
6. View Bridge Ports > []
Please select item <1 to 5>
ESC-prev.menu; !-main menu; &-exit
Figure
5-14. Bridge Monitoring Menu
³ To view bridge statistics:
• Navigate to Main Menu> Monitoring> Bridge > Statistics.
The Bridge Statistics menu appears as illustrated in
Figure
5-15
. To switch
to the next port or the previous port, type F or B respectively.
³ To view the parameters of a specific bridge port:
• In the Bridge Monitoring menu, type M anywhere in the row representing a
bridge port.
The entry is displayed as a menu containing the physical and logical
parameters of the specific bridge port.
³ To clear statistics for a bridge port:
1. Following the previous procedure, select a port for which to view bridge
statistics.
2. Type C to clear statistics for the selected bridge port.