Installation and Operation Manual Chapter 4 Configuration
Egate-100 Ver. 4.0 Configuring Egate-100 for Operation 4-35
Table
4-12. Syslog Parameters
Parameter Description Possible Values
Device logging
status
Determines whether logging to
the Syslog server is enabled or
disabled. When disabled,
Egate-100 logs the events
internally.
Default: Disabled
Enabled
Disabled
Device UDP
port
The local UDP port from which the
Syslog messages are sent.
Default: 514
Note: The port cannot be changed
when the logging status is
enabled.
1–65535
Facility Identifies the software module,
task or function from which the
Syslog messages are sent.
Default: Local 1
Local 1 – Local 7
Severity level Only events that their severity
equals or exceeds
the selected
severity level are sent.
Default: Minor
Critical – corresponds to the
Emergency (0) severity level of
Syslog
Major – corresponds to the Alert
(1) and Critical (2) severity levels
of Syslog
Minor – corresponds to the Error
(3) severity level of Syslog
Warning – corresponds to the
Warning (4) severity level of
Syslog
Event – corresponds to the Notice
(5) severity level of Syslog
Info – corresponds to the
Informational (6) severity level of
Syslog
Debug – corresponds to the
Debug (7) severity level of Syslog.
³ To configure the Syslog server parameters:
1. From the Syslog menu (Configuration > System > Syslog), select Server
Parameters.
The Server Parameters menu is displayed (see
Figure
4-35
).
2. Configure the Server parameters according to
Table
4-13
.
3. Select Save.