Installation and Operation Manual Chapter 5 Monitoring and Diagnostics
Egate-100 Ver. 4.0 Monitoring Performance 5-9
Egate-100
Main Menu> Monitoring> Logical Layer> Statistics
Type > (GFP)
Link State ... (Out Of Sync)
Rx Data Type Not Valid ... (0)
RX Single Error Corrected ... (0)
Rx tHEC Multi Error ... (0)
Rx eHEC Multi Error ... (3)
Rx CRC 32 Error ... (0)
1. Port number [1-126] ... (4)
>
Please select item <1 to 1>
F - Next port; B – Previous port; C – Clear
ESC-prev.menu; !-main menu; &-exit
Figure
5-13. Logical Layer Statistics Menu (GFP)
Table
5-2. Logical-layer Statistics Parameters
Parameter Description
Rx HDLC FCS The number of received HDLC frames with HDLC FCS errors
Rx HDLC Abort The number of received HDLC frames with HDLC Abort indication
PPP TX Fragments The number of MLPPP fragments transmitted over the specified
logical link. (The size of the fragment package is based on the
configured MTU.)
PPP RX Fragments The number of received MLPPP fragments packages on the
specified logical link. (The size of the fragmented package is
based on the remote device MTU.)
MP Rx Overflow Event The number of MLPPP sequence-number overflow events at the
receiver. This indicates that the receiver cannot resequence and
assemble the received frames because of excessive loss of
frames at the E1/T1 links or a large delay at one of the links (
larger than the device’s maximum compensation delay of 16ms)
Link state This status has two modes:
In_Sync: the RX GFP frame delineation process is in sync state
Out_of_sync: the RX GFP frame delineation process is in out of
sync state.
Rx GFP Data Type
Not Valid
This counter is incremented on every packet arriving to a GFP
machine with a GFP type different from Ethernet Over GFP
Rx Single Bit Error
Corrected
This counter increments on every frame in which the GFP
machine detected a single-bit error in one of the following fields
of the GFP headers: Chec, Thec, or Ehec
The statistics does not distinguish among the different types.