Chapter 4 Configuration Installation and Operation Manual
4-38 Configuring Egate-100 for Operation Egate-100 Ver. 4.0
Parameter Description Possible Values
Interval (15
minutes)[0-96]
15 minutes time interval in order to check the
counters value
Default: 0
0-96
³ To configure SDH/SONET administrative status and alarms:
1. Navigate to Main Menu > Configuration > Physical Layer >SDH/SONET >
Administrative Status & Alarms.
The Administrative Status & Alarms menu appears as illustrated in
Figure
4-38
.
Egate-100
...>Configuration>Physical Layer>SDH/SONET>Administrative Status & Alarms
1. Port Number > (1)
2. Port Name > (Port SDH-1)
3. Administrative Status > (Up)
4. Alarms > (Unmasked)
Please select item <1 to 5>
F - Forward Port; B - Backward Port; S - Save
ESC-prev.menu; !-main menu; &-exit
Figure
4-38. Administrative Status & Alarms Menu
2. Select Port Number, and then select the desired port number.
3. Select Port Name, and then select the desired port name.
4. Select Administrative Status, and then select Up or Down to enable or disable
the SDH/SONET link respectively.
5. Select Alarms and specify whether to display (unmask) or to not display
(mask) them.
When the SDH/SONET Administrative Status is set to Down, the SYNC indicator
(LED) is turned off.
³ To configure SDH/SONET E1/T1:
1. Navigate to Main Menu > Configuration > Physical Layer >SDH/SONET > E1/T1.
The E1/T1 menu appears as illustrated in
Figure
4-39
.
Note