Chapter 7 Application Tutorial Installation and Operation Manual
7-8 User and Management Traffic Separated by VLAN Egate-100 Ver. 4.0
To assign an IP address the first time the unit is powered up, or after resetting
the unit to the factory default, you must connect an ASCII terminal to the
CONTROL interface and use HyperTerminal to access the Egate-100 menus.
³ To set the host IP parameters:
1. Navigate to Configuration>System>Management>Host and set the host IP
parameters as illustrated in
Figure
7-9
.
Egate-100
Main Menu> Configuration> System> Management> Host
1. IP Address ... (192.188.10.10)
2. IP Mask ... (255.255.255.0)
3. Default Gateway ... (192.188.10.1)
4. Read Community ... (public)
5. Write Community ... (private)
6. Trap Community ... (public)
7. Encapsulation >
Please select item <1 to 7>
ESC-prev.menu; !-main menu; &-exit
Figure
7-9. Configuring Host Parameters
2. Navigate to Host>Encapsulation and set the host encapsulation parameters
as illustrated in
Figure
7-10
.
Egate-100
Main Menu> Configuration> System> Management> Host>
Encapsulation
1. Host Tagging > (Tagged)
2. Host VLAN ID[1 - 4094] ... (100)
3. Host Priority Tag[0 - 7] ... (0)
Please select item <1 to 3>
ESC-prev.menu; !-main menu; &-exit
Figure
7-10. Configuring Host Encapsulation
³ To add the network manager:
1. Navigate to Main Menu>Configuration>System>Management>Manager List.
2. Move the cursor to the Manager IP cell you wish to change by clicking <Tab>.
The selected cell is highlighted and the value is displayed in the
Change Cell field.
3. Select Change Cell, and enter 192.188.10.11 for the selected network
manager.
Setting Ethernet Parameters
The Gigabit Ethernet ports must be configured for operation if the default values