Chapter 4 Configuration Installation and Operation Manual
4-36 Configuring Egate-100 for Operation Egate-100 Ver. 4.0
Egate-100
Configuration> System> Syslog >Server Parameters
Server Sequence ... (1)
Server Access > (Disable)
1. Server IP Address ... (190.72.140.100)
2. Server UDP Port[1-65535] ... (514)
>
S-Save
ESC-Previous menu; !-Main menu; &-Exit
Figure
4-35. Syslog Server Parameters Menu
Table
4-13. Syslog Server Parameters
Parameter Description Possible Values
Server
Sequence
Server sequence number
Default: 1
1–5
Server Access Server access parameter
Default: Disabled
Enabled
Disabled
Server IP
Address
IP address of the Syslog server to which the
event logs are sent.
0.0.0.0 –
255.255.255.255
Server UDP Port The UDP port of the Syslog server.
Default: 514
Note: The port cannot be changed when the
logging status is enabled.
1–65535
Setting Physical Layer Parameters
Egate-100 has SDH/SONET or Channelized T3 ports, depending upon installation
option, as well as Gigabit Ethernet ports. The SDH/SONET, T3, and Gigabit
Ethernet configuration menus are accessed from the Physical Layer menu.
If you need to make a change to the configuration of SDH/SONET or T3 physical
ports, you must first clear any mapping of these ports to the logical ports. The
Egate-100 device provides a read-only mapping table that describes the
SDH/SONET tributary mapping to physical E1/T1 ports (see
Figure
4-47
and
Figure
4-48
).
Configuring the SDH/SONET Ports
³ To configure SDH/SONET ports:
1. Navigate to Main Menu > Configuration > Physical Layer.
The Physical Layer menu appears as illustrated in
Figure
4-36
.