Installation and Operation Manual Chapter 4 Configuration
Egate-100 Ver. 4.0 Additional Tasks 4-111
Parameter Description Possible Values
Stratum This parameter indicates the quality of the NTP
server. The lower the number, the higher the
quality, therefore if there are multiple servers
you should select the server with the lowest
stratum as the preferred NTP server.
Note: If no timestamp has been received from
the server, or if counter overflow occurs in the
parameter Received ddd:hh:mm:ss Ago, ‘--‘ is
displayed.
Last Timestamp Last date and time received from the NTP
server, in format:
dd-mm-yyyy
hh:mm:ss
Note: If no timestamp has been received from
the server, or if counter overflow occurs in the
parameter Received ddd:hh:mm:ss Ago, ‘--‘ is
displayed.
Received
ddd:hh:mm:ss Ago
Displays elapsed time since date and time were
received from the NTP server, in format
ddd:hh:mm:ss
Note: If no timestamp has been received from
the server, or if counter overflow occurs in this
paramete then ‘--‘ is displayed.
Resetting Egate-100
Egate-100 supports two types of reset:
• Reset all parameters to their factory defaults
• Restart the device.
Resetting to Factory Defaults
You can reset Egate-100 to its default configuration settings. For a complete list
of the configuration defaults, refer to
Chapter 3
.
³ To reset Egate-100 to the default settings:
1. Navigate to Main Menu > System > Factory Defaults.
Egate-100 displays the following message:
The device parameters will be set to defaults. Unit must
be reset. Do you want to proceed? (Y/N)
2. Type Y to confirm your request.
The device enters user mode, where you cannot configure parameters.