Chapter 4 Configuration Installation and Operation Manual
4-46 Configuring Egate-100 for Operation Egate-100 Ver. 4.0
Parameter Description Possible Values
Alarms High VC level alarms.
For SDH: per port
For SONET: Per VC3 per port
For each port, or range of ports, select
the port number and specify whether to
mask or unmask alarms
Default: Unmasked
Masked
Unmasked (default)
³ To configure HVC event threshold:
1. Navigate to Main Menu > Configuration > Physical Layer >SDH/SONET > HVC
and select Event Threshold.
The HVC Event Threshold menu appears as illustrated in
Figure
4-44.
Egate-100
Main Menu> Configuration> Physical Layer> SDH/SONET> >HVC
>Event Threshold (Port Number 1)
Counter Rising Falling
Path ES (0) (0)
Path SES (0) (0)
Path CV (0) (0)
Path UAS (0) (0)
FE-Line ES (0) (0)
FE-Line SES (0) (0)
FE-Line CV (0) (0)
FE-Line UAS (0) (0)
1. Change Cell [0-65535]
>
Please select item <1 to 1>
F - Forward; B - Backward
ESC-prev.menu; !-main menu; &-exit
Figure
4-44. HVC Event Threshold Menu
2. Configure event threshold parameters according to
Table
4-21.
Table
4-21. HVC Event Threshold Parameters
Parameter Description Possible Values
Counter Displays the event
threshold counter
Path ES – Path ES threshold value for sending
event log and trap
Path SES – Number of path severely errored
seconds (SES) in the current interval. A second
is considered to be a severely errored second if
multiple error events of the types described for
ES occurred.
Path CV - Number of path coding violations (CV)
in the current interval: a coding violation is
declared when a Bit Interleaved Parity (BIP)