RADview-HPOV/ATM User’s Manual Chapter 4 RADview-HPOV System Functions
Net Statistics 4-73
Change of Network Management Station Time
If the Network Management Station time is changed, it will cause a loss or
duplication of intervals the next time the files are written to. After that there will be
no problem. The loss of intervals occurs when the Network Management Station
time is set back. The duplication of intervals occurs when the Network
Management Station time is set ahead.
The tables for VC and VP contain too many variables to be able to get them in one
SNMP request. Therefore, several files will be created and a file grouping utility is
provided. For the PM tables there may be forward and/or backward directions. If
this table is requested, there should be space in the file for both directions, and if
only one is defined, the Statistical Information Collecting Application inserts -1s for
the other. Files will be automatically grouped at the end of the day.
Setting Variables
A configuration file is used for the purpose of saving statistical information and is
called (in the case of ACE101):
/opt/MNG/MNGVIEWHP/WAN/StatConfig/ac1_ NetStatisticsVariablesList
The file contains the names of the requested tables preceded by a # and followed
by the requested variable names that belong to this table. A comma follows each
word. The word NULL should end the list of variables for each table.
The following example is part of a file that describes the "#atmVpIntervalTable"
and the "#atmLoopbackVpIvlTable" tables and their variables.
#atmVpIntervalTable,atmVpIntervalVpi,atmVpIntervalNumber,atmVpIntervalR
xCellsClp01,atmVpIntervalRxCellsClp0,atmVpIntervalGcra0Violations,atmVpIn
tervalGcra1Violations,atmVpIntervalRxAIS,atmVpIntervalTxAIS,atmVpIntervalR
xRDI,atmVpIntervalTxRDI,atmVpIntervalContinuityLoss,atmVpIntervalUAS,atm
VpIntervalSES,atmVpIntervalCDC,NULL,
#atmLoopbackVpIvlTable,atmLoopbackVpIvlIfIndex,atmLoopbackVpIvlVpi,atm
LoopbackVpIvlIvl,atmLoopbackVpIvlOperStatus,atmLoopbackVpIvlCDV,atmLo
opbackVpIvlAverageDelay,atmLoopbackVpIvlMaxDelay,atmLoopbackVpIvlMin
Delay,NULL,
You can edit the ac1_NetStatisticsVariablesList file using any text editor so that
only the appropriate variables will be gathered from that type of device.
A variable can be added only if the agent supports it. Consult RAD’s Technical
Support before adding variables.