5620 Model Descriptor for LA-110 User’s Manual Chapter 4 Port Configuration and Monitoring
CES E1 Port Configuration 4-49
Parameters
To configure CES E1 port parameters:
1. In the LA-110 Node Draw, select the CES E1 port, right-click and select
Configure > Parameters.
Figure 4-34. CES E1 Port –Parameters
2. Fill in the fields, as described in Table 4-25.
3. Click <Save> to save the changes.
If the Line Type is changed to “Unframed”, a confirmation message
appears: “Changing line type to Unframed requires device reset.
Operation will RESET the device. Do you wish to continue?” Click <Yes>
to confirm.
If the Line Type is changed from “Unframed”, a confirmation message
appears: “Changing line type to Framed requires device reset. Operation
will RESET the device. Do you wish to continue?” Click <Yes> to confirm.