Chapter 5 Cross Connection 5620 Model Descriptor for LA-110 User’s Manual
5-30 Deleting Cross Connections
Table 5-19. OAM Loopback Statistics Parameters
Parameter Remarks
VPI The VPI value of the VC.
Read-only
VCI The VPI value of the VC.
Read-only
Rx Loopback
Requests
Total number of loopback requests received by the device on a VC.
Read-only
Rx Loopback
Responses
Total number of loopback responses that were received as a result of loopback transmitted
by the device.
Read-only
Tx Loopback
Requests
Total number of loopback requests transmitted by the device on a VC.
Read-only
Tx Loopback
Responses
Total number of loopback responses transmitted by the device on a VC.
Read-only
Successful
Loopback
Total number of loopbacks that were requested by the device and for which there was a
response.
Read-only
Failed
Loopback
Total number of loopbacks that were requested by the device and for which there was no
response
Read-only
Minimum
Delay (µsec)
The minimum delay.
Read-only
Average Delay
(µsec)
The average delay without including lost cells.
Read-only
Maximum
Delay (µsec)
The maximum delay without including lost cells.
Read-only
5.4 Deleting Cross Connections
In the Navigator, you can manually delete selected cross connections.
To delete a cross connection
In the Navigator, select the relevant Connection object(s), and on the Object
menu, click <Delete>.
The selected Connection object(s) is deleted.
It is also possible to simultaneously delete (up to 10) multiple cross connections by
selecting them and following the above steps.