Chapter 5 Cross Connection 5620 Model Descriptor for LA-110 User’s Manual
5-20 Configuring Cross Connections
Table 5-12. CES VC Connection – Loopback Test Parameters
Parameter Remarks
VPI The VPI value of the VC.
0…31
Read-only
VCI The VCI value of the VC.
0…255
Read-only
Loopback Test
Mode
Single, Periodic
Single Mode
Result
OK, Failed
Periodic Mode
Loopback
Failure
Indication
Disabled (default), Enabled
Loopback
Failure
Threshold
1 (default)…16
Enabled only if Loopback Fail Indication is enabled
Loopback Test
Status
Activates a loopback test on the specified port.
Off, Running
Action Activates a loopback test on the specified port.
Activate Test, Stop Test
FR VC Connections
Basic tasks include viewing and configuring:
Connection Info
Activating/deactivating connections
Loopback testing.
Connection Information
This menu will be enable only when application mode = FR.
To view FR VC connection information parameters:
In the Navigator, select the FR VC Connections container, right-click and
select Configure > Connections Info.