5620 Model Descriptor for LA-110 User’s Manual Chapter 4 Port Configuration and Monitoring
SHDSL Port Monitoring 4-67
Table 4-35. SHDSL Port – Physical Layer – Intervals Data Statistics Parameters (Cont.)
Parameter Remarks
To (hh:mm) The end time of the interval in hours and minutes.
Read-only
Errored Seconds The number of Errored Seconds.
Read-only
Severely Errored
Seconds (SESs)
The number of Severely Errored Seconds.
Read-only
CRC Anomalies The number of CRC anomalies.
Read-only
Loss of Sync
Word Seconds
(LOSWs)
The number of Loss of Sync Word Seconds
Read-only
Unavailable
Seconds (UASs)
The number of Unavailable Seconds.
Read-only
Accumulated Data Statistics
The Accumulated Data Statistics dialog shows running counters, as described
previously.
To view accumulated data statistics of the SHDSL port:
In the LA-110 Node Draw, select the SHDSL port, right-click and select
Monitor > Physical Layer > Accumulated Data.
A Monitor form appears, displaying the accumulated data statistics results
as shown in Figure 4-45 and as listed in Table 4-33.