Chapter 5 Cross Connection 5620 Model Descriptor for LA-110 User’s Manual
5-16 Configuring Cross Connections
Table 5-9. Transparent CES VC Connections Info Parameters (Cont.)
Parameter Valid Ranges/Remarks
Bundle Used to assist the NMS in selecting a value for the bundle index.
1-31
Read-only
Continuity Check The VCC admin status.
Off Two Way (down), On Two Way (up), On-source, On-sink
Read-only
Rx
10…47
Read-only
Tx
10…47
Read-only
Parity
Off, On
Read-only
Signaling The signaling mode
Read-only
Last Change This field indicates the time of the last change on the port.
Read-only
Table 5-10. Unframed CES VC Connections Info Parameters
Parameter Valid Ranges/Remarks
VPI The VPI value of the VC.
0…31
Read-only
VCI The VCI value of the VC.
0…255
Read-only
AAL1 Type
CES, DBCES, Transparent
Read-only
Operation Status
Up, Down
Read-only
Note: AAL1 Type can only be transparent in the case of an Unframed CES VC
connection
.