User's Manual Chapter 5 Performance Management
LRS-24 RADview/TDM Monitoring Modem Performance 5-3
To view/run tests on a modem:
1. In the Zoom view, select the modem (near end or far end), right click and
select Diagnostics > Test.
The DTE1 Testing dialog box displays the current tests running on the
modem. For descriptions of the fields, see
Table 5-1
.
Figure 5-1. DTE1 Testing Dialog Box
2. If the Interface Type is IR (ETH/UTP, ETH/BNC, IP/UTP, ETH/Q) a confirmation
message appears “Activating Loops may cause wrong information in the
routing tables”.
3. Press <OK> to confirm.
4. To run a new test on the modem, in the Activate Loops field, from the drop-
down list, choose the desired test, and click <Apply> (adjacent to the Active
Loops field).
5. To stop all tests running on the modem, in the Loops area, click <Stop>
(adjacent to the Current Loops field).
6. To set the polling interval on the modem, click <Polling> (available only if the
test being run is BERT, as shown in the Current Loops field, shown in the
figure above).