User's Manual Chapter 3 Configuration Management
LRS-24 RADview/TDM Setting Operational Parameters 3-39
Parameter Possible Values / Remarks
LLB Enable Disable, Enable (when checked)
Disabled if the interface type is X.21, G.703 (64k), Ethernet, ETH/BNC, ETH/Q, IP/UTP,
G.703-E1, G.703-T1
Line
Clock Source Clock Source is read-only for the far-end modem.
Local-Int; Remote-Rcv
Local-Rcv; Remote-Int
Local-Ext-Auto; Remote-Rcv (N/A with Ethernet or ETH/BNC)
Local-Rcv; Remote-Ext-Auto (N/A with Ethernet or ETH/BNC)
Tx Level (dBm) –6, 0, 4, 10 for version 1.0
0, 4, 10 for versions > 2.0
Both ASMi-50 units must be new versions (ASMi-50-1) or both are old
versions.
For the older 2-wire version, SET is enabled in Modem Mode; however, if the
modem is Slave-Temp you cannot change the Modem Mode.
Note