Chapter 3 Configuration Management User's Manual
3-28 Setting Operational Parameters LRS-24 RADview/TDM
Figure 3-25. Ports Configuration Dialog Box – E1 Tab
3. Fill in the fields, as described in
Table 3-6
, which lists some of the Ports
Configuration dialog box parameters. For descriptions of additional fields
relevant to specific modem types, see the following section
.
4. Click <Set> to implement the changes. ([Set] is disabled for Interface Type
(IR) = NO IR.
Configuring Modem Port Parameters
To configure the port parameters, set the Modem Mode as Master. If the Modem
Mode is set to Slave, the ports configuration parameters are not configurable.)
Viewing and Modifying the Modem Mode is not applicable for ASMi-51CD,
ASMi-51-CQ, ASMi-51 or ASMi-52CD/CD4W/CQ units. Modem Mode does not work
for ASMi-50, versions≥ 0.8x.
For instructions on how to set the modem mode, refer to
Viewing and Modifying
the Modem Mode
General limitations for various Ports Configuration fields are as follows:
• For the DTE Rate field, RADview checks the selectable values for both the
near and far ends. Only the common values are displayed in the dialog boxes
of both modems. If no common values are found, then the selectable list is
available for each modem separately.