Chapter 1 Edit Configuration Mode RADview-PC/TDM Megaplex-2100/2104 User’s Manual
1-30 System Level Configuration Operations
3. Click <Set> in the Variant Data dialog box (Figure 1-30).
Figure 1-31. Change Variant TS Dialog Box – Gen. Tab
Table 1-13. V5.1 Variants Parameters – Gen. Tab
Parameter Possible Values / Remarks
TS Time Slot
1..31
TS Type Time Slot Type
NC, PSTN, ISDN B1, ISDN B2, C Channel, Permanent B1, Permanent B2, Semi-
Permanent B1, Semi-Permanent B2
Port ID IO Port ID this TS is connected to
0..16777215
EF/L3 Address Address of the IO port this TS is connected to. IO port is identified according to its
Address:
for ISDN ports: EF Address. Valid values: 0..8175
for PSTN ports: L3 Address. Valid values: 0..32767
65535=notApplicable (FFFF).
NA, 0..32768
Slot Slot containing the IO port this TS is connected to
NA, IO-1..IO-12
Port IO Port this TS is connected to
NA, external-1..external-16, internal-1.. internal-2