RADview-PC/TDM Megaplex-2100/2104 User’s Manual Chapter 2 Agent Configuration Mode
Table 2-9. R2 Data TS Data Parameters
Parameter Possible Values / Remarks
Signaling Profile The profile number selected in the Select Profile dialog box
1 to 5
General Tab
R2 Mode
Auto
, Manual
Country
ITU–T
, Korea, India, Brazil (continuous), Brazil (pulsed),
Argentina, 7, 8, 9, 10
R2 Delay
Terrestrial
, Satellite
Metering Indication
C Bit
, B Bit
Timers Tab
Break-Make Ratio (msec)
56–44, 64–36
, 80–20
Release Guard T2 (msec)
16..2000
Regret Duration (sec)
14
..120
Seize Detect (msec)
24..448
Seize Ack. Delay (msec)
8
..304
Clear-Back Detect (msec)
24
..448
Clear-Forward Detect (msec)
200..504
Fault Detect (msec)
16..104
Fault Removal Detect (msec)
16..104
Meter Pulse Duration (msec)
120..304
Seize Ack. Wait (msec)
104..1200
Seize Ack. Detect (msec)
48
..600
Answer Detect (msec)
64..448
Block Removal Detect (msec)
16
..96
Metering Pulse Detect (msec)
64..448
Forced Disconnect Detect (msec)
304..448
Disconnect Ack. Detect (msec)
304..448
Release Guard T1 (msec)
16..2000
TS Data Tab
TS
1..31
Call Enable
Both
, Incoming, Outgoing
Metering
Yes, No
System Level Agent Operations 2-19