Chapter 2 Agent Configuration Mode RADview-PC/TDM Megaplex-2100/2104 User’s Manual
2. Click <Apply>.
Defining Scope of Alarm Reports
Using the Reports command, you can define the scope, type and severity of alarm
reports that you will receive at the network management station.
To define an alarm report:
1. In the Fault menu, click Alarms, followed by Configuration and Reports…
The Alarm Report dialog box appears.
2. Set the desired severity level for each report: Event, Warning, Minor, Major,
or Critical.
3. Click <Set>.
Figure 2-33. Alarm Report Dialog Box
Table 2-18. Alarm Report Parameters
Parameter Possible Values / Remarks
Trap Define whether you want to receive traps for all alarms or for only those alarms of at
least a certain severity.
Alarm On Severity - Minimum level of severity required for sending a trap to the
network management station. Trap severity must be equal or higher than buffer severity.
Alarm Off Severity - Maximum level of severity allowed for a trap not to be sent to the
network management station.
2-36 Megaplex Level Fault Operations