RAD Data comm FOM-E3 Especificações Página 54

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 53
Chapter 4 Configuration Installation and Operation Manual
4-14 Configuring for Operation RICi-E3, RICi-T3 Ver. 1.0
Configuring the T3 Port
RICi-T3 includes a T3 port. You can configure its parameters at the physical level
as follows:
To configure the T3 port:
1. From the Physical Ports menu, select T3.
The T3 menu appears as illustrated in
Figure 4-11
.
RICi-T3
Configuration > Physical Ports >T3
1. Administrative Status (Up)
2. Framing (M23)
3. Tx Clock (LBT)
4. Line Build Out (Up to 225ft)
5. Protocol (LAPS)
ESC-prev menu; !-main menu; &-exit 1 user(s)
Figure 4-11. T3 Menu
2. From the T3 menu, configure the following:
Administrative Status
Up – the network port is enabled
Down – the network port is disabled.
Framing. Specifies the framing type
M23
C-bit.
Tx Clock. Specifies the clock
Internal Clock
LBT.
Line Build Out for Line Mode = DSU. The length of a cable in feet between
T3 port connector and the network access point
Up to 225 feet – 0 to 225 ft
Over 225 feet – 225 ft and further.
Protocol. Specifies the encapsulation
HDLC
LAPS.
3. Select Save to complete the user T3 port configuration.
The selected value shows in the T3 Port configuration menu.
Vista de página 53
1 2 ... 49 50 51 52 53 54 55 56 57 58 59 ... 101 102

Comentários a estes Manuais

Sem comentários