Chapter 4 Configuration Installation and Operation Manual
4-16 Configuring for Operation RICi-E3, RICi-T3 Ver. 1.0
Configuring the MAC Table
Static MAC addresses are stored in the MAC table.
To add a static MAC address:
1. From the Bridge menu, select Static MAC Table.
The Static MAC Table appears as illustrated in
Figure 4-13
.
RICi-E3, RICi-T3
Configuration>Applications>Bridge>Static MAC Table
| Address | Received Bridge Port |
+________________________________________________+
| 00–00–12–34–54–55 | E3 |
| 00–00–44–44–44–44 | ETH |
| 00–12–23–23–23–23 | ETH |
+________________________________________________+
ESC-prev menu; !-main menu; &-exit; ?-help
Figure 4-13. Static MAC Table
2. In the Static MAC Table, press <A> to add a static MAC address.
The Static MAC table switches to the Add mode as illustrated in
Figure 4-14
.
RICi-E3, RICi-T3
Configuration>Applications>Bridge>Static MAC Table
1. MAC Address ... (000000000000)
2. Receive Bridge Port > (UNDEFINED)
3. Save
>
ESC-prev menu; !-main menu; &-exit; 1 user(s)
Figure 4-14. Static MAC Table, Add Mode
3. In Add mode, perform the following:
Select MAC Address, and enter a new MAC address.
Select Receive Bridge Port, and choose a RICi-E3, RICi-T3 interface this
MAC address will be attached to.
Select Save All to save the MAC address.
Press <Esc> to return to the Static MAC table.
To remove a static address from the table:
From the Static MAC Table, select the desired MAC address, and then press
<R>.
The selected MAC address is deleted from the table.
Vista de página 55
1 2 ... 51 52 53 54 55 56 57 58 59 60 61 ... 101 102

Comentários a estes Manuais

Sem comentários

Teledyne Above ground pool accessories user manuals

The list of Teledyne Above ground pool accessories products contains 2 user manuals for 2 models. All pdf user’s guides are available for download or viewing online.

Click on an alphabet below to scroll to the full list of models starting with that letter

Models Document Type
EHE
User Manual   Teledyne EHE User's Manual, 34 pages
LLG
User Manual   Teledyne LLG User's Manual, 25 pages