ASMi-450
High-Speed HDSL Modem
Installation and Operation Manual
Notice
This manual contains information that is proprietary to RAD Data Communications. No part of this
publication may be reproduced in any form whatsoever without prior written approval by RAD Data
Communications.
No representation or warranties for fitness for any purpose other than what is specifically mentioned in this
manual is made either by RAD Data Communications or its agents.
For further information contact RAD Data Communications at the address below or contact your local
distributor.
RAD data communications
Headquarters
12 Hanechoshet Street
Tel Aviv 69710 Israel
Tel: 972-3-6458181
Fax: 972-3-6498250
RAD data communications
US East
900 Corporate Drive
Mahwah, NJ 07430 USA
Tel: (201) 529-1100
Fax: (201) 529-5777
RAD data communications
US West
7711 Center Avenue #350
Huntington Beach, CA 92647 USA
Tel: (714) 897-2448
Fax: (714) 891-1764
© 1997 RAD Data Communications Ltd. Publication No. 634-200-11/97
Vista de página 0
1 2 3 4 5 6 ... 116 117

Resumo do Conteúdo

Página 1 - ASMi-450

ASMi-450High-Speed HDSL ModemInstallation and Operation ManualNoticeThis manual contains information that is proprietary to RAD Data Communications. N

Página 2 - Warranty

Contentsx ASMi-450 Installation and Operation Manual

Página 3 - Telecommunication Safety

Connector WiringA-2 ASMi-450 Installation and Operation ManualTable A-2. V.36/RS-449/422 DCE Interface Adapter CablePin Designation Direction Function

Página 4 - Regulatory Information

Connector WiringASMi-450 Installation and Operation Manual A-3A.2 V.35 DCE ConnectorWhen the ASMi-450 is ordered with an V.35 DCE interface, the phys

Página 5 - Declaration of Conformity

Connector WiringA-4 ASMi-450 Installation and Operation ManualA.3 X.21 DCE ConnectorWhen the ASMi-450 is ordered with an X.21 interface, the physical

Página 6

Connector WiringASMi-450 Installation and Operation Manual A-5A.4 HDSL Line ConnectorThe HDSL line is terminated in an eight-pin RJ-45 connector, des

Página 7

Connector WiringA-6 ASMi-450 Installation and Operation ManualA.6 Ethernet Interface ConnectorWhen the ASMi-450 is ordered with an Ethernet interface

Página 8

ASMi-450 Installation and Operation Manual B-1Appendix BSNMP ManagementB.1 ScopeThis Appendix provides the specific information required for the manag

Página 9

SNMP ManagementB-2 ASMi-450 Installation and Operation ManualB.2 SNMP EnvironmentGeneralThe SNMP management functions of the ASMi-450 are provided by

Página 10 - Contents

SNMP ManagementASMi-450 Installation and Operation Manual B-3The Management Information BaseThe management information base (MIB) includes a collectio

Página 11 - List of Figures

SNMP ManagementB-4 ASMi-450 Installation and Operation ManualIn addition, the ASMi-450 SNMP agent supports the RAD-private (enterprise-specific) MIB.•

Página 12

SNMP ManagementASMi-450 Installation and Operation Manual B-5When an SNMP message is received by the addressed entity, first it checks theoriginator&a

Página 13 - List of Tables

ASMi-450 Installation and Operation Manual xiList of FiguresFigure 1-A. Typical Application for ASMi-450 with Data Interface ...

Página 14

SNMP ManagementB-6 ASMi-450 Installation and Operation ManualB.3 IP EnvironmentGeneralThe SNMP agent of the ASMi-450 communicates using the Serial Lin

Página 15 - Quick-Start Guide

SNMP ManagementASMi-450 Installation and Operation Manual B-7• Host Portion. The host portion is used to identify an individual hostconnected to the

Página 16 - 2. Configuration Procedure

SNMP ManagementB-8 ASMi-450 Installation and Operation ManualB.4 SNMP TrapsThe SNMP agent of the ASMi-450 supports the standard MIB-II traps. Inadditi

Página 17 - 3. Command Index

ASMi-450 Installation and Operation Manual C-1Appendix CInstallation in 19" RacksC.1 GeneralThe ASMi-450 can be installed in 19" racks. Unit

Página 18

Installation in 19" RacksC-2 ASMi-450 Installation and Operation ManualC.2 Installation of Single UnitThe rack adapter kit for single unit insta

Página 19 - Introduction

Installation in 19" RacksASMi-450 Installation and Operation Manual C-3C.3 Installation of Two UnitsGeneralThe two-unit rack adapter kit include

Página 20 - Ethernet Interface

Installation in 19" RacksC-4 ASMi-450 Installation and Operation Manual• Fasten one short adapter bracket to the left-hand side wall of the unit

Página 21 - HDSL Subsystem

ASMi-450Installation Instructions forCompliance with EMC RequirementsTo comply with electromagnetic compatibility requirements,two ferrite cores shoul

Página 22 - System Timing

List of Figuresxii ASMi-450 Installation and Operation Manual

Página 23 - Operation

ASMi-450 Installation and Operation Manual xiiiList of TablesTable 3-A. ASMi-450 Controls, Connectors and Indicators ...

Página 24

List of Tablesxiv ASMi-450 Installation and Operation Manual

Página 25

ASMi-450 Installation and Operation Manual Quick-Start Guide - 1Quick-Start GuideIf you are familiar with HDSL transmission equipment, use this guide

Página 26 - 1.2 Operating Environment

Quick-Start GuideQuick-Start Guide - 2 ASMi-450 Installation and Operation Manual2. Configuration ProcedureYou are ready to start ASMi-450 configurati

Página 27 - System Functions

Quick-Start GuideASMi-450 Installation and Operation Manual Quick-Start Guide - 33. Command IndexDisplay the index of commands by typing the help comm

Página 28 - 1.3 Technical Specifications

Quick-Start GuideQuick-Start Guide - 4 ASMi-450 Installation and Operation ManualNotes

Página 29

ASMi-450 Installation and Operation Manual 1-1Chapter 1Introduction1.1 Functional DescriptionPurpose and MainFeaturesThe ASMi-450 is a high-speed HDSL

Página 30

WarrantyThis RAD product is warranted against defects in material and workmanship for a period of one year fromdate of shipment. During the warranty p

Página 31 - Installation

Introduction1-2 ASMi-450 Installation and Operation Manual• Ethernet 10BaseT interface. The interface can use unshielded and shieldedtwisted pair (UT

Página 32 - 2.3 Site Requirements

IntroductionASMi-450 Installation and Operation Manual 1-3The interface includes a full-feature remote bridge, that operates at the physicaland data l

Página 33 - Opening ASMi-450

Introduction1-4 ASMi-450 Installation and Operation Manual• The remote unit, located at the remote end of the link (customer side),serves as the netw

Página 34 - Functions

IntroductionASMi-450 Installation and Operation Manual 1-5Figure 1-D. Flow of Timing Signals through ASMi-450 System in the Internal Timing Mode• ASM

Página 35 - . ASMi-450 Internal Settings

Introduction1-6 ASMi-450 Installation and Operation ManualThe remote management functions are performed through a serial RS-232 portthat enables seria

Página 36

IntroductionASMi-450 Installation and Operation Manual 1-7Test and Diagnostics CapabilitiesThe ASMi-450 has comprehensive diagnostics capabilities. AS

Página 37 - ASMi-450 Cover

Introduction1-8 ASMi-450 Installation and Operation Manual1.2 Operating EnvironmentThis section describes the HDSL environment, with special emphasis

Página 38 - 2.5 Connections

IntroductionASMi-450 Installation and Operation Manual 1-9By reducing the line symbol rate, the maximum range that can be reached isincreased. This is

Página 39 - Connections

Introduction1-10 ASMi-450 Installation and Operation Manual1.3 Technical SpecificationsHDSL InterfaceSignal Format 2B1Q line codingLine Type One uncon

Página 40 - Connection

IntroductionASMi-450 Installation and Operation Manual 1-11Ethernet InterfaceCompliance IEEE 802.3Interface Type 10BaseT for use on UTP and STP mediaI

Página 41 - Instructions

Safety WarningsThe exclamation point within a triangle is intended to warn the operator or servicepersonnel of operation and maintenance factors relat

Página 42

Introduction1-12 ASMi-450 Installation and Operation ManualWord Format− One start bit− 7 or 8 data bits− Parity: none, odd, or even− One stop bitConne

Página 43 - Indicators

ASMi-450 Installation and Operation Manual 2-1Chapter 2Installation2.1 GeneralThe ASMi-450 is delivered completely assembled. It is designed for insta

Página 44 - Display Functions

Installation2-2 ASMi-450 Installation and Operation Manual2.2 UnpackingA preliminary inspection of the equipment container should be made beforeunpack

Página 45

InstallationASMi-450 Installation and Operation Manual 2-32.4 ASMi-450 Configuration InformationGeneralThis paragraph provides information on the fun

Página 46 - Push-buttons

Installation2-4 ASMi-450 Installation and Operation ManualFigure 2-1. Identification of Cover ScrewsJumper and SwitchLocation andFunctionsThe ASMi-450

Página 47

InstallationASMi-450 Installation and Operation Manual 2-5Figure 2-2. ASMi-450 Internal Settings

Página 48 - Designation Function Values

Installation2-6 ASMi-450 Installation and Operation ManualDIP switch S1 allows the user to control the reloading of the desired group ofdefault parame

Página 49

InstallationASMi-450 Installation and Operation Manual 2-7NoteUser-selected parameter values are not erased by setting one or more switchsections to O

Página 50 - 3.6 Operating Instructions

Installation2-8 ASMi-450 Installation and Operation Manual2.5 ConnectionsConnectorLocationFigure 2-3 shows typical rear panels of ASMi-450 units, and

Página 51 - Normal Indications

InstallationASMi-450 Installation and Operation Manual 2-9WarningBefore switching on this instrument and before connecting any other cable,the protect

Página 52 - Turn-off

Regulatory InformationFCC-15 User InformationThis equipment has been tested and found to comply with the limits of the Class A digital device, pursuan

Página 53 - Configuration

Installation2-10 ASMi-450 Installation and Operation Manualfirst the interface adapter cable to the RS-530connector, then connect the user's data

Página 54 - Step Action Key Display

ASMi-450 Installation and Operation Manual 3-1Chapter 3Front-Panel OperatingInstructions3.1 ScopeIn this chapter you will find detailed instructions f

Página 55 - Guidelines

Front-Panel Operating Instructions3-2 ASMi-450 Installation and Operation Manual3.2 Front Panel Controls, Connectors, and IndicatorsFigure 3-1 shows

Página 56

Front-Panel Operating InstructionsASMi-450 Installation and Operation Manual 3-3Ethernet InterfaceIndicatorsFigure 3-2 shows the indicators located on

Página 57

Front-Panel Operating Instructions3-4 ASMi-450 Installation and Operation Manual3.3 Control of ASMi-450 Operation, GeneralGeneralASMi-450 operating m

Página 58

Front-Panel Operating InstructionsASMi-450 Installation and Operation Manual 3-5Status MessagesWhen the ASMi-450 is not being configured and no test i

Página 59 - ASMi-450 Control

Front-Panel Operating Instructions3-6 ASMi-450 Installation and Operation ManualOrganization ofASMi-450 DisplayThe ASMi-450 display has two rows:• Up

Página 60 - 4.2 Hardware Requirements

Front-Panel Operating InstructionsASMi-450 Installation and Operation Manual 3-7If you make an incorrect selection, the selection is not accepted. In

Página 61

Front-Panel Operating Instructions3-8 ASMi-450 Installation and Operation Manual3.4 System Configuration ParametersTable 3-3 lists the available syst

Página 62 - Function

Front-Panel Operating InstructionsASMi-450 Installation and Operation Manual 3-93.5 Control Port Configuration ParametersTable 3-4 lists the availabl

Página 63 - Terminal

Declaration of ConformityManufacturer’s Name:RAD Data Communications Ltd.Manufacturer’s Address:12 Hanechoshet St.Tel Aviv 69710Israeldeclares that th

Página 64 - Protocol

Front-Panel Operating Instructions3-10 ASMi-450 Installation and Operation Manual3.6 Operating InstructionsThis paragraph covers the following activit

Página 65 - Commands

Front-Panel Operating InstructionsASMi-450 Installation and Operation Manual 3-11Step Action Key Display1 Bring the cursor under the top row (if notal

Página 66 - Command Purpose Options

Front-Panel Operating Instructions3-12 ASMi-450 Installation and Operation ManualIn Table 5-1, you will find two types of alarms, designated as ON/OFF

Página 67 - CLR ALM [/A]

Front-Panel Operating InstructionsASMi-450 Installation and Operation Manual 3-133.7 Local Configuration Set-Up ProcedureBefore starting any configur

Página 68 - DEF AGENT

Front-Panel Operating Instructions3-14 ASMi-450 Installation and Operation ManualStep Action Key Display1 Bring the cursor under the top row (if notal

Página 69 - DEF NAME

Front-Panel Operating InstructionsASMi-450 Installation and Operation Manual 3-15Step Action Key Display9 After completing the configuration actions,y

Página 70 - DEF NODE

Front-Panel Operating Instructions3-16 ASMi-450 Installation and Operation ManualSP PARAMETERSSee parameter definitions in Section 3-5.SPEED_BPS Selec

Página 71

Front-Panel Operating InstructionsASMi-450 Installation and Operation Manual 3-173.8 LCD Configuration Error MessagesThe ASMi-450 detects configurati

Página 72

Front-Panel Operating Instructions3-18 ASMi-450 Installation and Operation ManualNotes

Página 73

ASMi-450 Installation and Operation Manual 4-1Chapter 4ASMi-450 Controlfrom the Control Port4.1 GeneralThis Chapter provides detailed instructions for

Página 75

ASMi-450 Control from the Control Port4-2 ASMi-450 Installation and Operation Manual4.2 Hardware RequirementsTerminalCharacteristicsAny standard ASCII

Página 76

ASMi-450 Control from the Control PortASMi-450 Installation and Operation Manual 4-3Interface TypeControl Line DCE DTECTS Out Not usedDCD Out Out

Página 77

ASMi-450 Control from the Control Port4-4 ASMi-450 Installation and Operation Manual• When the node address is 0, the DCD line is always ON (active).

Página 78 - DSP ST PORT [Option]

ASMi-450 Control from the Control PortASMi-450 Installation and Operation Manual 4-54.3 Preparation for Use of Supervision TerminalASMi-450Preparatio

Página 79 - DSP ST SYS [option]

ASMi-450 Control from the Control Port4-6 ASMi-450 Installation and Operation Manual4.4 ASMi-450 Supervision LanguageThis paragraph presents the ASMi

Página 80 - H<CR>

ASMi-450 Control from the Control PortASMi-450 Installation and Operation Manual 4-7• The address is in the range of 1 through 255 (0 indicates that

Página 81

ASMi-450 Control from the Control Port4-8 ASMi-450 Installation and Operation ManualTable 4-A. ASMi-450 Command Set IndexCommand Purpose OptionsCLR AL

Página 82

ASMi-450 Control from the Control PortASMi-450 Installation and Operation Manual 4-94.5 ASMi-450 Command Set DescriptionThis section describes the AS

Página 83

ASMi-450 Control from the Control Port4-10 ASMi-450 Installation and Operation ManualCLR TST----------------------------------------------------------

Página 84 - - Single ASMi-450

ASMi-450 Control from the Control PortASMi-450 Installation and Operation Manual 4-114. A typical display, as seen after all the parameters are select

Página 85 - Control Session

ASMi-450 Installation and Operation Manual viiContentsChapter 1 Introduction1.1 Functional Description...

Página 86 - Ending a Control

ASMi-450 Control from the Control Port4-12 ASMi-450 Installation and Operation Manual2. The ASMi-450 displays the node name entry form:ENTER NODE NAME

Página 87

ASMi-450 Control from the Control PortASMi-450 Installation and Operation Manual 4-132. The password entry screen appears, e.g.:NEW PASSWORD (4 to 8 C

Página 88

ASMi-450 Control from the Control Port4-14 ASMi-450 Installation and Operation ManualNotesIn addition to the parameters listed in Section 3-5, the fol

Página 89 - Diagnostics

ASMi-450 Control from the Control PortASMi-450 Installation and Operation Manual 4-15DEF SYS----------------------------------------------------------

Página 90

ASMi-450 Control from the Control Port4-16 ASMi-450 Installation and Operation Manual Terminal Type TV- 920 VT-52 VT-100 Freedom-110 Freedom-220Cl

Página 91

ASMi-450 Control from the Control PortASMi-450 Installation and Operation Manual 4-17Table 4-B. Control Terminal Alarm MessagesAlarm No. Alarm Syntax

Página 92

ASMi-450 Control from the Control Port4-18 ASMi-450 Installation and Operation ManualTable 4-2. Control Terminal Alarm Messages (Cont’d)Alarm No. Alar

Página 93

ASMi-450 Control from the Control PortASMi-450 Installation and Operation Manual 4-19Table 4-2. Control Terminal Alarm Messages (Cont’d)Alarm No. Alar

Página 94 - 5.3 Test Functions

ASMi-450 Control from the Control Port4-20 ASMi-450 Installation and Operation ManualDisplayFormatA typical HDSL line status display is shown below.ST

Página 95 - Operating

ASMi-450 Control from the Control PortASMi-450 Installation and Operation Manual 4-21on the remote unit.REMOTE UNIT Displays the state of the loopback

Página 96 - 5.4 Power-Up Self-Test

Contentsviii ASMi-450 Installation and Operation ManualOrganization of ASMi-450 Display...

Página 97

ASMi-450 Control from the Control Port4-22 ASMi-450 Installation and Operation ManualF----------------------------------------------------------------

Página 98

ASMi-450 Control from the Control PortASMi-450 Installation and Operation Manual 4-23INIT DB ---------------------------------------------------------

Página 99 - Connector Wiring

ASMi-450 Control from the Control Port4-24 ASMi-450 Installation and Operation ManualLOOP-------------------------------------------------------------

Página 100

ASMi-450 Control from the Control PortASMi-450 Installation and Operation Manual 4-25RESET -----------------------------------------------------------

Página 101 - A.2 V.35 DCE Connector

ASMi-450 Control from the Control Port4-26 ASMi-450 Installation and Operation Manual4.6 Control Terminal Operating InstructionsBefore using the cont

Página 102 - A.3 X.21 DCE Connector

ASMi-450 Control from the Control PortASMi-450 Installation and Operation Manual 4-27NoteWhile the control terminal is in session with the ASMi-450, t

Página 103 - A.4 HDSL Line Connector

ASMi-450 Control from the Control Port4-28 ASMi-450 Installation and Operation Manual• When you see the correct and complete command in the echo line

Página 104

ASMi-450 Control from the Control PortASMi-450 Installation and Operation Manual 4-294.7 Configuration Error MessagesThe ASMi-450 provides configurat

Página 105 - SNMP Management

ASMi-450 Control from the Control Port4-30 ASMi-450 Installation and Operation ManualNotes

Página 106 - B.2 SNMP Environment

ASMi-450 Installation and Operation Manual 5-1Chapter 5Diagnostics5.1 GeneralThe ASMi-450 diagnostics functions include:• Status indications and mess

Página 107

ContentsASMi-450 Installation and Operation ManualixActivating the Test Functions from a Control Terminal...

Página 108 - Management

Diagnostics5-2 ASMi-450 Installation and Operation ManualTable 5-A. ASMi-450 Alarm Buffer MessagesMessage Description Corrective ActionsAlarmTypeLAN N

Página 109

DiagnosticsASMi-450 Installation and Operation Manual 5-3Table 5-1. ASMi-450 Alarm Buffer Messages (Cont’d)Message Description Corrective ActionsAlarm

Página 110 - B.3 IP Environment

Diagnostics5-4 ASMi-450 Installation and Operation ManualTable 5-1. ASMi-450 Alarm Buffer Messages (Cont’d)Message Description Corrective ActionsAlarm

Página 111

DiagnosticsASMi-450 Installation and Operation Manual 5-5Table 5-1. ASMi-450 Alarm Buffer Messages (Cont’d)Message Description Corrective ActionsAlarm

Página 112 - B.4 SNMP Traps

Diagnostics5-6 ASMi-450 Installation and Operation Manual5.3 Test FunctionsTest FunctionsThe ASMi-450 supports the following types of test functions:•

Página 113 - Appendix C

DiagnosticsASMi-450 Installation and Operation Manual 5-7LOOP REM REM PORTWhen the remote user's port loopback is activated, the user's port

Página 114

Diagnostics5-8 ASMi-450 Installation and Operation Manual(Cont’d)Step Action Key Display4 Bring the cursor under the left-hand field inthe second row,

Página 115 - Preparations

DiagnosticsASMi-450 Installation and Operation Manual 5-95.5 Troubleshooting InstructionsIn case a problem occurs, check the displayed alarm messages

Página 116 - Fastening the Two

Diagnostics5-10 ASMi-450 Installation and Operation ManualTable 5-2. Troubleshooting Chart (Cont’d)No. Trouble Symptoms Probable Cause Corrective Meas

Página 117

ASMi-450 Installation and Operation Manual A-1Appendix AConnector WiringA.1 RS-530 DCE Connector and Adapter CablesWhen the ASMi-450 is ordered with