Appendix D Command Language Installation and Operation Manual
D-24 Supervisory Terminal Commands FCD-E1
DEF DOWNLOAD
Purpose
Define the inband management communication parameters. Refer to Table D-6
for the parameter description, allowable ranges and configuration guidelines.
Syntax
DEF DNLOAD {ML SL}
Use
1. To define the inband management communication parameters for the link,
type:
DEF DNLOAD ML<Enter> or DEF DNLOAD SL<Enter>
The first line of the data form is displayed. A typical line is shown below:
DNLOAD MODE
NONE
If you specify the sublink for an FCD-E1/*, you will see ERROR 054 (illegal
parameter for current configuration).
2. Select the desired mode, and then press <Enter>.
If the DEDIC TS mode is selected the following line of the data form appears:
TS_NUM SPEED
1 8
3. Select the desired timeslot and management data rate, in kbps. For sublinks,
always select 8 kbps.
4. When done, press <Enter> to end.
If the FRAME RL mode is selected the following line of the data form appears:
TS_NUM SPEED
1 64
5. Select the desired timeslot. The management data rate is always 64 kbps. This
selection is available for the main link only.
6. When done, press <Enter> to end.
DEF DP
Purpose
Define the communication parameters of the dial-out port and control the use of
the call-out function. The communication parameters of the dial-out port can be
different from the communication parameters of the supervisory port, which are
selected by means of the DEF SP command.
Syntax
DEF DP
Note