FCD-IPM Installation and Operation Manual Chapter 5 Setup Menu
Interface Parameters Menu 5-51
E1 Setup Menu
This section describes the parameters in the E1 Setup menu.
E1 Setup: LINK 1 (Device name – FCD-IPM)
------------------
1. Clock Master: [Link 1]
2. Multiplier : [64 kbps]
3. Time slots mapping
4. General Diagnostics
5. E1 parameters
6. Additional Cards parameters
7. Alarms filter
8. Advanced Setup
ESC – Return to previous menu
Choose one of the above:
Figure 5-56. E1 Setup Menu
Table 5-19. E1 Setup Parameters
Parameters Possible Values Description
Clock Master
Internal
Link 1
I/O1 SUB E1
I/O2 SUB E1
FIX SUB E1
Selects the source clock that synchronizes the whole E1
network
FCD-IPM generates the system source clock from an internal
clock oscillator.
FCD-IPM recovers the clock from the data received from the
E1 link1
For FCD-IPM with a sublink
FCD-IPM recovers the clock from the data received from one
of the E1 sublinks
Multiplier
56 kbps, 64 kbps
Sets the data rate of each DATA time slot.
Vista de página 140