Appendix D IR-IP Interface Module Installation and Operation Manual
D-32 Erasing IR-IP Software ASM-40 Ver. 1.0
If you do not set sections 1 and 2 to OFF within 15 seconds of power-up, the IP
router card ignores the setting of all the four sections to ON and starts normal
operation. In this case, it is recommended to turn ASM-40 off and then back on.
To abort the whole operation, turn ASM-40 off, return all the four-switch section
to the desired positions, and then turn ASM-40 on again.
5. Turn ASM-40 off, and the return all the four sections of the DIP switch to the
desired positions.
D.14 Erasing IR-IP Software
You may erase the IR-IP application software, without erasing the user-defined
parameters.
After the application software is erased, IR-IP starts its TFTP server application,
and waits for the downloading of software by a TFTP client connected to its LAN
interface. The procedure to be used to download the application software in this
case is also described below.
You may want to erase the application software if the downloading of new
software using the Device Control menu (see
Figure D-17
) fails, and IR-IP does
not function properly.
Erasing Application Software
To erase the application software:
1. Turn ASM-40 off.
2. Set all the four sections of IR-IP DIP switch to ON.
3. Turn ASM-40 on and monitor the IP router ERR indicator: it must turn on and
start blinking.
4. While the ERR indicator is blinking (within 15 seconds), set sections 3 and 4
of the DIP switch to OFF.
When the ERR indicator stops blinking and lights steadily, the IP router
configuration becomes erased.
If you do not set sections 3 and 4 to OFF within 15 seconds of power-up, IR-IP
ignores the setting of all the four sections to ON and starts normal operation. In
this case, it is recommended to turn ASM-40 off and then back on.
Alternately, to abort the whole operation, turn ASM-40 off, return all the four
switches to the desired positions, and then turn ASM-40 on again.
5. Turn ASM-40 off, and the return all the four sections of the DIP switch to the
desired positions.
Downloading New Software
After erasing the application software, you can download new software from any
computer that can serve as a TFTP client.