
Chapter 4 Troubleshooting and Diagnostics Installation and Operation Manual
4-8 Viewing Alarm Status ASM-40CD Ver. 1.0
MODEM ALARM STATUS
MODEM NAME : ASM40CD(m)
DEFINE MODEM PORT NUMBER : 1
SELECT MODEM : MODEM 1 LOCAL
LINE DISCONNECT : OFF
REMOTE MODEM POWER OFF : OFF
TRANSMIT CARRIER : OFF
RECEIVE CARRIER : OFF
LLB BY DTE : OFF
RLB BY DTE : OFF
SYNC LOSS : ON
CONFIGURATION MISMATCH : OFF
NVRAM FAILED : OFF
ILLEGAL EXTERNAL CLOCK SOURCE : OFF
NO MANAGEMENT LINK : ON
NO MODEM PORT (IR) : ON LAN NOT CONNECTED : OFF
NO FIBER INTERFACE : OFF NO EXT CLK INPUT : OFF
IR RATE MISMATCH : OFF ILL. CLK-ERR : OFF
SELF TEST FAILED : OFF OLD REM VERSION : OFF
XILINX FAILED : OFF WRONG CONNECTION : OFF
MINOR ALARM - AIS-ELEC : OFF AIS-OPT : OFF
MAJOR ALARM - LINE DISCON.-ELEC : OFF LINE DISCON.-OPT : OFF
Figure 4-6. Modem Alarm Status Screen
Bolded rows in
Figure 4-6
indicate fields applicable to ASM-40CD and standalone
modems. Additional, non-bolded parameters listed on a screen apply to other
modems installed in the LRS-24 hub.
The function and options available for each highlighted parameter or alarm
message are summarized in
Table 4-2.
Table 4-2. Modem Alarm Status Screen
Parameter Type Function Option Option indicates
LLB BY DTE Read LLB comand was issued
by DTE
Modem 1 Local
Modem 2 Local
LLB
RLB BY DTE Read RLB comand was issued
by DTE
Modem 1 Local
Modem 2 Local
RLB
ON Modems are not locked SYNC LOSS Read Viewing the alarm state
OFF Modems are locked
ON A non-volatile RAM failure
was detected. The
NVRAM contains the
system configuration.
NVRAM FAILED Read Viewing the alarm state
OFF No NVRAM failure was
detected
Comentários a estes Manuais