Installation and Operation Manual Chapter 4 Troubleshooting and Diagnostics
ASM-40CD Ver. 1.0 Setting Loopback and BER Tests 4-5
4.2 Internal BERT Circuit Operation
ASM-40CD has a built-in BERT circuit consisting of a pattern generator and a
pattern tester. This circuit acts in conjunction with the V.54 diagnostic loops and
remote BERT to verify normal system operation and isolate faulty equipment in
the event of system failure. Each of the modems on the card has a separate BERT
circuit.
Activating the BER tester simultaneously activates the pattern generator, which
sends a 511-bit pattern according to the ITU V.52 standard.
If errors are detected by the BER tester, the ERR LED flashes or remains ON.
Figure 4-4
shows the data flow from the pattern generator to the pattern tester
in the local BERT circuit.
Figure 4-4. ASM-40CD BER System Test
4.3 Setting Loopback and BER Tests
The Modem Diagnostic menu (
Figure 4-5
) provides information on diagnostic
options and enables you to set loopback connections and to test the BER. The
BER can be evaluated over a portion or the entire transmission system, using
either the built-in BERT circuit or external equipment.
To initiate a loopback and BERT:
Type: NODEnn DEF TST <Enter>.
The Modem Diagnostic menu appears (see
Figure 4-5
).
nn is slot number, from 1 to 12.
Note