RAD Data comm IPmux-1E Especificações Página 107

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 143
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 106
IPmux-1/1E Installation and Operation Manual Appendix E Parameters and Screens
General Configuration E-9
Alarm Traps Mask
Each of the IPmux-1/1E alarms can activate a trap toward the NMS. It is possible to
enable/disable the trap operation for each one of the alarms, using the Alarm Trap
Mask screen.
ALARM TRAPS MASK
1. Alarm ID <refer to Manual> 1
2. Trap Status Active
Alarm Active Traps:
Select item from the menu.
Use <Esc> key or keys <1> to <2>
Figure E-12. Alarm Traps Mask Menu
Table E-4. Alarm Traps Mask Parameters
Parameter Possible Values Remarks
Alarm ID
1, 2, 6, 8, 21, 26, 27
IPmux-1/1E alarm
Trap Status
Active
Masked
Generates an alarm
Does not send an alarm
Default for all traps: Masked
Table E-5. IPmux-1/1E Alarms
Alarm ID Alarm Description Trap Sent to NMS
1 Loss of Signal (LOS Physical Layer) Alarm LOS
1.3.6.1.4.1.164.6.1.3.0.7
2 Loss of Frame (LOF Physical Layer) Alarm LOF
1.3.6.1.4.1.164.6.1.3.0.8
6 Alarm Indication Signal Received (AIS
Line Physical Layer)
Alarm AIS
1.3.6.1.4.1.164.6.1.3.0.10
8 Remote Defect Indication Received (RDI
Line Physical Layer)
Alarm RDI
1.3.6.1.4.1.164.6.1.3.0.11
21 Far End Block Error (FEBE Line Layer) Alarm FEBE
1.3.6.1.4.1.164.6.1.3.0.12
26 Local Connectivity Fail Local Conn Status Trap
1.3.6.1.4.1.164.6.1.3.0.13
27 Remote Connectivity Fail Remote Conn Status Trap
1.3.6.1.4.1.164.6.1.3.0.14
Main Menu
2. Configuration
1. General
Configuration
3. Management
Configuration
3. Alarm Traps
Mask
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com
Vista de página 106
1 2 ... 102 103 104 105 106 107 108 109 110 111 112 ... 142 143

Comentários a estes Manuais