122 Rockwell Automation Publication 750-TD001H-EN-P - June 2013
PowerFlex 750-Series AC Drives
Specifications - Safety Options
Safe-Torque -Off Safe Speed Monitor
Standards: IEC/EN60204-1, ISO13489-1, IEC 61508, IEC 61800-5-2 IEC/EN60204-1, ISO12100, IEC 61508, IEC 61800-5-2
Safety Category: Cat. 3 and PL(e) per EN ISO 13849-1; SIL CL3 per IEC 61508 and EN 62061 Cat. 4 and PL(e) per EN ISO 13849-1; SIL CL3 per IEC 61508 and EN 62061
Power Supply (user I/O): 24V DC ±10%, 0.8…1.1 x rated voltage
(3)
PELV or SELV
(3) Safety outputs need additional fuse for reverse voltage protection of the control circuit. Install a 6 A slow-blow or 10 A fast-acting fuse.
Power Consumption: 4.4 W 36 W
Safety Enable (SE+, SE–): 24V DC, 22 mA, short-circuit protected –
Safety Power (SP+, SP–): 24V DC, 35 mA, short-circuit protected –
SLS Outputs (68, 78): – 24V DC, 50mA, short-circuit protected
SS Outputs (34, 44): – 24V DC, 50 mA, short-circuit protected
Door Control Outputs (51, 52): – 24V DC, short-circuit protected, 0.75 A bipolar (Power to Release/Power to
Lock) configuration.
20 mA, cascading (2Ch Source) configuration.
Pulse Outputs (S11, S21): – 24V DC, 50 mA, short-circuit protected
Pulse Inputs (S12, S22, S32, S42, S52, S62,
S72, S82, X32, X42):
– 5 mA per input, max
Input ON Voltage, Minimum: 24V DC ±10%, 21.6…26.4V DC 15V
Input OFF Voltage, Maximum: 5V 5V
Input OFF Current, Maximum: 2.5 mA @ 5V DC 2 mA
Input-to-Output Response Time (SS_In,
SLS_In, DM_In, ESM_In, LM_In):
– 20 ms
Overspeed Response Time: – User-configurable
Inputs (S34): – 5 mA per input, max
Conductor Size
(1)
:
(1) Refer to Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1.
0.3…0.8 mm
2
(28…18 AWG) 0.25…2.5 mm
2
(24…14 AWG)
Strip Length: 10 mm (0.39 in.) 6 mm (0.25 in.)
Terminal Screw Torque – 0.2…0.25 N•m (1.8…2.2 lb•in)
Certification
(2)
(2) When product is marked.
c-UL-us UL Listed, certified for US and Canada.
CE European Union 2004/108/EC EMC Directive, and EU 2006/42/EC Machinery Directive
EN 61800-3; categories C2 and C3
EN 62061; EM Immunity
EN ISO 13849-1
EN ISO 13849-2
EN 61800-5-1
EN 61800-5-2
EN 61508 Parts 1-7
C-Tick Australian Radiocommunications Act, compliant with: EN 61800-3; categories C2 and C3
TÜV TÜV Certified for Functional Safety: up to SIL CL3, according to EN 61800-5-2,
EN 61508, and EN 62061; up to Performance Level PL(e) and Category 3,
according to EN ISO 13849-1; when used as described.
TÜV Certified for Functional Safety: up to SIL CL3, according to EN 61800-5-2,
EN 61508, and EN 62061; up to Performance Level PL(e) and Category 4,
according to EN ISO 13849-1; when used as described.