Appendix A Pinouts Installation and Operation Manual
A-6 V.35 Connectors Optimux-34 Ver. 2.81
Table
A-6. V.35/Telebras Pinout
Pin Number Pin Name Pin Description Type
(Input/Output)
1 GND Ground GND
2 TDA Transmit data A Input
3 TXCA Transmit clock A Output
4 RDA Receive data A Output
5 RTS Request To Send Input
6 RXCA Receive clock A Output
7 CTS Clear To Send Output
8 LLB Local Loopback Input
9 DSR Data Set Ready Output
10 DCD Data and Carrier Detect Output
11 EXTCA External clock A Input
12 TEST_MODE Test Mode Output
13 GND Ground GND
14 NC Not connected
15 TDB Transmit data B Input
16 TXCB Transmit clock B Output
17 RDB Receive data B Output
18 NC Not connected
19 RXCB Receive clock B Output
20 NC Not connected
21 NC Not connected
22 NC Not connected
23 RLB Remote Loopback Input
24 EXTCB External clock B Input
25 NC Not connected