User’s Manual Chapter 3 Configuration Management
RV-EMS/NGN LA-210 Setting the System Parameters 3-5
Table
3-2. Date & Time Dialog Box Parameters
Parameter Possible Values / Remarks
Date System date.
Format: yyyy-mm-dd
Note: Can be set when Mode is Unicast Client.
Time System time.
Format: hh:mm:ss
Note: Can be set when Mode is Unicast Client.
SNTP
Mode SNTP mode.
Disable
Unicast Client
Time Zone SNTP time zone.
GMT–12:00
GMT–11:00
GMT–1:00
GMT
GMT+1:00
GMT+12:00
Note:
Disabled when Mode is
Disable
.
Enabled when Mode is Unicast Client.
Server IP Address IP address of the SNTP server.
Note:
Disabled when Mode is Disable.
Enabled when Mode is Unicast Client.
Update Interval (min) SNTP update interval in minutes. Period of time after which LA-210 polls the
SNTP server.
1…1440
Note:
Disabled when Mode is Disable.
Enabled when Mode is Unicast Client.
.