Chapter 2 Installation and Setup FOM-E1/T1 Installation and Operation Manual
2-2 Installation and Setup
2.3 Installation and Setup
FOM-E1/T1 is a standalone device intended for tabletop or bench installation. It is
delivered completely assembled. No provision is made for bolting the unit on the
tabletop.
To install FOM-E1/T1:
1. Determine the required configuration of FOM-E1/T1 and set the internal
jumpers accordingly (see Configuring FOM-E1/T1 below).
2. Connect the line (see Connecting the Fiber Optic Interface below).
3. Connect the DTE (see Connecting the E1/T1 Interface below).
4. Connect power to the unit (see Connecting the Power below).
Access to the inside of the equipment is permitted only to authorized and
qualified service personnel.
To avoid accidental electric shock, always disconnect the interface cables and
the power cord before removing the unit from its casing.
Line voltages are present inside FOM-E1/T1 when it is connected to power
and/or to the lines. Moreover, under external fault conditions dangerous
voltages may appear on the lines connected to the unit.
Any adjustment, maintenance, and repair of the opened instrument under
voltage should be avoided as much as possible and, when inevitable, should
be carried out only by a skilled technician who is aware of the hazard involved.
Capacitors inside the instrument may remain charged even after the
instrument has been connected from its power supply source.
FOM-E1/T1 contains components sensitive to electrostatic discharge (ESD). To
prevent ESD damage, avoid touching the internal components. Before moving
jumpers, touch the FOM-E1/T1 frame.
Configuring FOM-E1/T1
This section describes how to configure FOM-E1/T1 for a typical application.
Figure 2-1 illustrates the layout of the FOM-E1/T1 printed-circuit board. Table 2-1
provides details on the functions of the internal jumpers and switches, and their
default settings.
To configure FOM-E1/T1:
1. Disconnect all the cables connected to FOM-E1/T1.
2. Release the two rear panel screws and use them as levers to slide out the PCB
interior of the unit.
3. Select the E1/T1 electrical interface: E1 balanced, E1 unbalanced or T1 balanced by
setting the JP2, JP4, JP5, JP6, JP7 and JP8 jumpers to appropriate position.
4. If using E1 unbalanced interface, connect the BNC shield to the chassis ground by
setting the SW1 and SW2 switches to the CONNECTED position.
If you are using balanced E1/T1 connection, set the SW1 and SW2 switches to the
FLOATING position.
Warning
Caution
Vista de página 21
1 2 ... 17 18 19 20 21 22 23 24 25 26 27 ... 45 46

Comentários a estes Manuais

Sem comentários

Sagem 288140594 podręczniki

Instrukcje obsługi i podręczniki użytkownika dla Urządzenia wielofunkcyjne Sagem 288140594.
Dostarczamy 1 pdf podręczników Sagem 288140594 do pobrania za darmo według typów dokumentów: Arkusz Danych






Więcej produktów i instrukcji dla Urządzenia wielofunkcyjne Sagem

Modele Rodzaj dokumentu
MF 3720 Instrukcja Użytkownika    MF 6990dn, 6 strony
MF 5401 Dokumentacja   Sagem MF 5401 Specifications, 43 strony
MF 9331 Dokumentacja   Sagem MF 9331 Specifications, 40 strony
MF 3430 Instrukcja Użytkownika   Sagem MF 3430 User manual, 109 strony
MF 3780 Instrukcja Użytkownika   Sagem MF 3780 User manual [en] , 171 strony
MF 3725 Instrukcja Użytkownika   Sagem MF 3725 User manual [en] , 152 strony
LASER PRO 346 Instrukcja Użytkownika   Sagem LASER PRO 346 User manual, 116 strony
LASER PRO 346 Instrukcja Użytkownika   doc Laser Pro 346/348 en, 2 strony
LASER PRO 344 Podręcznik Użytkownika   Sagem LASER PRO 344 User`s guide, 45 strony
LASER PRO 348 Instrukcja Użytkownika   As configurações padrão do fabricante aparecem, 372 strony
MF 5482 Instrukcja Użytkownika    extensions de garantie [en] , 25 strony
MF 9331 Instrukcja Użytkownika   RÉCAP RÉUNION DU 1ER MARS 2010, 5 strony