Connection of Data and Telecommunications Cables
Data and telecommunication interfaces are classified according to their safety status.
The following table lists the status of several standard interfaces. If the status of a given port differs from
the standard one, a notice will be given in the manual.
Ports Safety Status
V.11, V.28, V.35, V.36, RS-530,
X.21, 10 BaseT, 100 BaseT,
Unbalanced E1, E2, E3, STM, DS-2,
DS-3, S-Interface ISDN, Analog voice
E&M
SELV Safety Extra Low Voltage:
Ports which do not present a safety hazard. Usually
up to 30 VAC or 60 VDC.
xDSL (without feeding voltage),
Balanced E1, T1, Sub E1/T1
TNV-1 Telecommunication Network Voltage-1:
Ports whose normal operating voltage is within the
limits of SELV, on which overvoltages from
telecommunications networks are possible.
FXS (Foreign Exchange Subscriber) TNV-2 Telecommunication Network Voltage-2:
Ports whose normal operating voltage exceeds the
limits of SELV (usually up to 120 VDC or telephone
ringing voltages), on which overvoltages from
telecommunication networks are not possible. These
ports are not permitted to be directly connected to
external telephone and data lines.
FXO (Foreign Exchange Office), xDSL
(with feeding voltage), U-Interface
ISDN
TNV-3 Telecommunication Network Voltage-3:
Ports whose normal operating voltage exceeds the
limits of SELV (usually up to 120 VDC or telephone
ringing voltages), on which overvoltages from
telecommunication networks are possible.
Always connect a given port to a port of the same safety status. If in doubt, seek the assistance of a
qualified safety engineer.
Always make sure that the equipment is grounded before connecting telecommunication cables. Do
not disconnect the ground connection before disconnecting all telecommunications cables.
Some SELV and non-SELV circuits use the same connectors. Use caution when connecting cables.
Extra caution should be exercised during thunderstorms.
When using shielded or coaxial cables, verify that there is a good ground connection at both ends. The
earthing and bonding of the ground connections should comply with the local codes.
The telecommunication wiring in the building may be damaged or present a fire hazard in case of
contact between exposed external wires and the AC power lines. In order to reduce the risk, there are
restrictions on the diameter of wires in the telecom cables, between the equipment and the mating
connectors.
Vista de página 6
1 2 3 4 5 6 7 8 9 10 11 12 ... 77 78

Comentários a estes Manuais

Sem comentários

Sagem 288140594 podręczniki

Instrukcje obsługi i podręczniki użytkownika dla Urządzenia wielofunkcyjne Sagem 288140594.
Dostarczamy 1 pdf podręczników Sagem 288140594 do pobrania za darmo według typów dokumentów: Arkusz Danych






Więcej produktów i instrukcji dla Urządzenia wielofunkcyjne Sagem

Modele Rodzaj dokumentu
MF 3720 Instrukcja Użytkownika    MF 6990dn, 6 strony
MF 5401 Dokumentacja   Sagem MF 5401 Specifications, 43 strony
MF 9331 Dokumentacja   Sagem MF 9331 Specifications, 40 strony
MF 3430 Instrukcja Użytkownika   Sagem MF 3430 User manual, 109 strony
MF 3780 Instrukcja Użytkownika   Sagem MF 3780 User manual [en] , 171 strony
MF 3725 Instrukcja Użytkownika   Sagem MF 3725 User manual [en] , 152 strony
LASER PRO 346 Instrukcja Użytkownika   Sagem LASER PRO 346 User manual, 116 strony
LASER PRO 346 Instrukcja Użytkownika   doc Laser Pro 346/348 en, 2 strony
LASER PRO 344 Podręcznik Użytkownika   Sagem LASER PRO 344 User`s guide, 45 strony
LASER PRO 348 Instrukcja Użytkownika   As configurações padrão do fabricante aparecem, 372 strony
MF 5482 Instrukcja Użytkownika    extensions de garantie [en] , 25 strony
MF 9331 Instrukcja Użytkownika   RÉCAP RÉUNION DU 1ER MARS 2010, 5 strony