Universal Media Converter and Repeater
AMC-101
ALARMS CONNECTOR
A dry circuit with a 9-pin D-type
connector on the rear panel, has
been added to the unit to signal
minor and major alarms. The dry
contact circuit is used to signal
the following alarms:
RED ALARM - Power Failure
(DC voltage on board)
YELLOW ALARM - Signal
Detect Failure (to any of the
unit modules)
CONFIG ALARM - Improper
Configuration (incompatible
modules and/or data rates
selected)
Three pins are dedicated for
each alarm: Common (COM),
OK and FAIL. The COM pin is
the input for each alarm. The
user can drive the COM pin with
any signal
(0 to 5V). If the signal is received
OK, the COM pin is connected to
its corresponding OK pin; If there
is a failure, the COM pin is
connected to its corresponding
FAIL pin (See
Figure 7
and
Table 1
for the connector pin
assignments).
Table 1. Connector Pin Assignment Table
PIN TYPE
ALARM TYPE COM OK FAIL
RED 9 4 5
YELLOW 3 8 7
CONFIG 6 2 1
Figure 7. Connector Pin Assignment
Table 2. Bridging Modules
Module
Name
Protocols
Supported
Cable
Type
Connector
Type
Range Impedance
10BT/B* Ethernet UTP Cat 5 Shielded RJ-45 100m
100
100BT/B** Fast Ethernet UTP Cat 5 Shielded RJ-45 80m
100
100BT/R*** Fast Ethernet UTP Cat 5 Shielded RJ-45 80m
100
* Remote Ethernet bridge module
** Remote Fast Ethernet bridge module
*** Media converter for Fast Ethernet (Tx to Fx)