RICi-4E1/T1, RICi-8E1/T1 Installation and Operation Manual Appendix Bl
B-4 Transferring the Software and Configuration Files RICi-4E1/T1, RICi-8E1/T1 Ver. 2.0
Downloading Application Files via TFTP
³ To download application file via TFTP
1. From the Boot Manager menu, select System Configuration.
2. Configure the IP parameters of RICi-4E1/T1, RICi-8E1/T1 (IP address, IP mask,
and default gateway). These parameters are valid only for the TFTP file
transfer via the Boot Manager.
3. Start a TFTP application.
4. Configure the TFTP communication parameters as follows:
Connection timeout – more than 30 seconds to prevent an automatic
disconnection wile deleting the backup partition, which takes about 25
seconds.
Block size – 512 bytes.
UDP port – 69.
5. Select a local software release file to download.
6. Enter the TFTP server IP address.
7. Start downloading.
RICi-4E1/T1, RICi-8E1/T1 automatically erases the backup partition (it takes
about 25 seconds). Once the downloading is completed, the RICi-4E1/T1,
RICi-8E1/T1 unit saves the new release as an active partition; the previously
active partition becomes a backup.