HCD-E1 Installation & Operation Manual Chapter 5 - Troubleshooting and Diagnostics
01/01/01 08:15 Performance Diagnostics Data 5-17
Table 5-3 Summary of E1 Performance Monitoring (Cont.)
Display Description Range
LST DEG MIN Last 24-hour count of degraded minutes. The display is updated every 24
hours.
0 - 1440
BPV COUNT The total number of BPV errors during the last minute The display is
updated every minute.
0 - 9999
BPV WORST The number of BPV errors measured during the worst minute. The
display is updated every minute.
0 - 9999
HDSL Performance
Monitoring
This section describes the performance evaluation and monitoring functions
provided by HCD-E1 with respect to the HDSL transmission performance on
each line.
The HDSL performance monitoring parameters are listed below:
•
• •
•
Current errored seconds (ES)
An errored second is any second containing one or more errored blocks,
or the occurrence of a severely disturbed period (SDP). The data is
collected for the current 15-minute interval.
•
• •
•
Current unavailable seconds (UAS)
An unavailable second is any second in which a failed signal state exists.
A failed signal state is declared when 10 consecutive severely errored
seconds (SES) occur, and is cleared after 10 consecutive seconds of data
are processed without a SES. The data is collected for the current 15
minute interval.
•
• •
•
Current severely errored seconds (SES)
A SES is a second with more than 30% errored blocks or one or more
SDP's. The data is collected for the current 15-minute interval.
•
• •
•
Current background block error (BBE)
A BBE is an errored block not occurring during an SES. The data is
collected for the current 15-minute interval.
•
• •
•
Errored Seconds Ratio (ESR)
The ratio of ES to the total seconds in the current 15-minute interval (not
displayed on the LCD).
•
• •
•
Severely errored seconds ratio (SESR)
The ratio of SES to the total seconds in the current 15-minute interval
(not displayed on the LCD).
Vista de página 156
1 2 ... 152 153 154 155 156 157 158 159 160 161 162 ... 231 232

Comentários a estes Manuais

Sem comentários

Pro-Form CrossWalk GTS manuels

Manuels d'utilisation et guides de l'utilisateur pour Tapis de course Pro-Form CrossWalk GTS.
Nous fournissons des manuels en pdf 3 Pro-Form CrossWalk GTS à télécharger gratuitement par type de document : Manuel de l'utilisateur






Plus de produits et de manuels pour Tapis de course Pro-Form

Modèles Type de document
Performance 1450 Manuel de l'utilisateur Pro Form Performance 1450, 39 pages
385ex Manuel de l'utilisateur   : _J _ ~ j - NYS Historic Newspapers, 1 pages
831.298301 Manuel de l'utilisateur   Pro-Form 831.298301 User`s manual, 22 pages
520 Manuel de l'utilisateur   Pro-Form 520 User`s manual, 28 pages
755 CROSSTRAINER Manuel de l'utilisateur   Pro-Form 755 CROSSTRAINER User`s manual, 30 pages
PFTL10110.0 Manuel de l'utilisateur   Pro-Form PFTL10110.0 User`s manual, 19 pages
780 ZLT Manuel de l'utilisateur BRUKSANVISNING - Mylna Sport Sverige, 33 pages
PETL12711.0 Manuel de l'utilisateur   Pro-Form PETL12711.0 User`s manual, 36 pages
XT 70 Manuel de l'utilisateur   XT series relay introduction flyer (Americas) - SCHRACK, 4 pages
Cross Walk plus Manuel de l'utilisateur   Pro-Form Cross Walk plus User`s manual, 28 pages
PETL40707.0 Manuel de l'utilisateur BRUKERVEILEDNING, 36 pages
831.299270 Manuel de l'utilisateur   Pro-Form 831.299270 User`s manual, 26 pages
J6 831.297693 Manuel de l'utilisateur   Pro-Form J6 831.297693 User`s manual, 18 pages