Appendix B Traffic Separation RIC-155 Installation and Operation Manual
B-8 Configuring for a Typical Application
MNG
1
1
2
2
1
1
1
1
Local RIC-155
Switch
Remote RIC-155
2
22
2
Host Host
Uplink
Uplink
Data
Management
Station
LAN LAN
Data
Figure B-10. Managing RIC-155 via Data Port
The units are configured as follows:
Local RIC-155:
Forwarding – Filter Tagged
Port Management Access – All
Host Tagging – Tagged
Host VLAN – 1
Host VLAN Priority – any from 0 to 7
Management and data ports – Tag stripping is disabled
Uplink port – Tag.
Remote RIC-155:
Forwarding – Filter Tagged
Port Management Access – None
Host Tagging – Untagged
Management and data ports – Tag stripping is enabled
Uplink port – Stack.