Chapter 4 Troubleshooting and Diagnostics IPmux-1/1E Installation and Operation Manual
4-6 Performance Monitoring and Troubleshooting Statistics
E1 Statistics
E1 over UTP
LOS: 0
LOF (Red) 0
LCV: 0
RAI (Yellow) 0
AIS: 0
FEBE: 0
BES: 0
SS: 0
SES: 0
UAS: 0
LOMF: 0
Time Since: 700 sec ------------------Valid Intervals 1---
1. Interval 0
ESC> Exit N. Next Inv
Figure 4-1. E1 Statistics
E1/T1 statistics are monitored and saved under consecutive Intervals. Each Interval
is 15 minutes long. There are 96 intervals, which represent the last 24 hours.
Whenever a new Interval is started, the counters are reset to zero. The old interval
shows the total of alarms that occurred during its 15-minute period.
The current active Interval is always marked as Interval 0 (you will see that the Time
Since counter is running). The previous Interval is marked as 1 and so on. The E1/T1
statistic counters cannot be reset manually. The user can browse the stored Intervals
by pressing N for the Next Interval or P for the Previous Interval.
The physical E1/T1 alarms are:
LOS
LOF (RED)
LCV
RAI (Yellow)
AIS
FEBE
Note
Vista de página 87
1 2 ... 83 84 85 86 87 88 89 90 91 92 93 ... 183 184

Comentários a estes Manuais

Sem comentários

Holux Navigators user manuals

The list of Holux Navigators products contains 2 user manuals for 2 models. All pdf user’s guides are available for download or viewing online.

Click on an alphabet below to scroll to the full list of models starting with that letter

Models Document Type
GPSmile Pocket PC
User Manual   Holux GPSmile Pocket PC User's Manual, 50 pages
GR-213U
User Manual   Holux GR-213U User's Manual, 10 pages